MAIN FEATURES OF Envirotech Stack Monitoring Kit VSS3
- Specially to monitor Dioxins, Furan & provision for monitoring of Heavy Metals emissions
- Collection based on wet chemical techniques
- Measures total quantity / volume of the emissions
- Heating Probe & box assembly with auto temp controller
- Rugged & convenient for sampling for long duration with oil free Vacuum Pump assembly
- Glass lining inside the nozzle, thimble holder & probe pipe
- Tripod stand for better accessibility
- Probe set accommodated in a carrying case
- Convenient to use
List of Components Envirotech Stack Monitoring Kit VSS3:
(1) :Instrument panel consisting of pyrometer, manometer rotameters, vacuum gauge, stop watch, dry gas meter & temperature controller. (2): Probe kit consisting of probe pipe, pitot tube, connecting hoses, tool kit, filter holder, nozzles, thermocouple, heating system, tripod etc. (3): Cold box assembly consisting of glass impingers, condenser glass coil, moisture bottle & water pump. (4): Vacuum pump assembly.
In addition Stainless Steel Probe, Hose Pipe, Thimble Holder, Set of 3 SS Nozzles, Set of 4 Glass Impingers (240ml.) for normal Stack Emission Monitoring also provided.
| Size and Weight (approx) : | Length (mm) | Width (mm) | Height (mm) | Weight (Net) Kg |
|---|---|---|---|---|
| VSS3 Instrument Panel | 400 | 250 | 400 | 10 |
| VSS3 Cold Box | 250 | 410 | 400 | 10 |
| VSS3 Probe Box | 1140 | 300 | 150 | 20 |
| Vacuum Pump Assembly | 340 | 200 | 280 | 13 |
| Glass Assembly Box | 1170 | 260 | 100 | 10 |
Warranty, all Envirotech products carry a one year warranty for trouble free operation against any manufacturing defect.
Envirotech Stack Monitoring Kit VSS3 SPECIFICATIONS
- Stack Temperature Range:Ambient to 600 deg C read on a Digital Pyrometer.
- Stack Velocity Range:3 to 60 m/sec
- Thermocouple:T/C sensor in SS 304 casing, length of insertion: 1 m with 2m long cable.
- Manometer:Digital with 0-1060 mm of H2O range
- Pitot Tube:Calibrated S-type fabricated -SS 304, 1m long
- Particulate Sampling:0 –30 lpm collection on thimble type filter up to 0.3 micron rating.
- Gaseous Sampling:0 – 3 lpm collection in a set of Borosilicate glass impingers.
- Rotameter:Acrylic body with 2% FSD accuracy, 0 – 30 lpm for PM and 0-3 lpm for GAS.
- Sampling Probe:1m long SS tube with inside lining of Teflon & provision for controlled at 120 deg C heating.
- Filter Holder:Glass filter holder with heating provision suitable to hold either cellulose filteration thimble (size 28mm lD X 100mm long) or glass fibre thimble (size 19mm lD X 90mm long).
- Nozzles:A set of 5 glass nozzles.
- Digital Clock:0-60 minutes, 1 second readout with start and stop switches.
- Temp. Controller:Digital type temperature controller.
- Dry Gas Meter:Range 0 to 60 LPM connected to SPM line.
- Sampling Train:4 Nos. of 275 ml cap glass impinger, 1 No. condenser glass coil, 1 No. moisture bottle 750 ml & 1 No. cartridge tube accommodated in separate ice tray with instrument panel with a provision to cool down flue gas temperature.
- Vacuum Pump:Monoblock Rotary Vane type, oil free, 0.5 HP single phase motor (230V) with more than 50 lpm free flow capacity.
- Envirotech Stack Monitoring Kit VSS3
Click to DOWNLOAD CATALOG for Envirotech Stack Monitoring Kit VSS3